Fibre Channel data transmission ranges
Port speed (Gbps) Cable size
(microns)
Short wavelength
(SWL)
Long wavelength
(LWL)
Extended long
wavelength (ELWL)
2 50 300 m (984 ft) (OM2)
500 m (1,640 ft)
(OM3)
N/A N/A
62.5 150 m (492 ft) N/A N/A
9 N/A 30 km (18.6 miles) N/A
4 50 150 m (492 ft) (OM2)
380 m (1,246 ft)
(OM3)
400 m (1,312 ft)
(OM4)
N/A N/A
62.5 70 m (230 ft) N/A N/A
9 N/A 30 km (18.6 miles) N/A
8 50 50 m (164 ft) (OM2)
150 m (492 ft) (OM3)
190 m (623 ft) (OM4)
N/A N/A
62.5 21 m (69 ft) N/A N/A
9 N/A 10 km (6.2 miles) or
40 km (24.8 miles)
N/A
10 50 82 m (269 ft) (OM2)
300 m (984 ft) (OM3)
550 m (1804 ft)
(OM4)
N/A N/A
62.5 33 m (108 ft) N/A N/A
9 N/A 10 km (6.2 miles) N/A
16 50 35 m (115 ft) (OM2)
100 m (328 ft) (OM3)
125 m (410 ft) (OM4)
N/A N/A
62.5 15 m (49 ft) N/A N/A
9 N/A 10 km (6.2 miles) N/A
Brocade DCX 8510 Technical Specifications
172 Brocade DCX 8510-8 Backbone Hardware Installation Guide